MIL-P-50307 (MU)
NONE DEFINED)
MINOR :
NOTE :
The tests in Table I shall be conducted in accordance with the test
condition requirements in the "Test Facilities" requirement of
MIL-F-13926.
-
4.3.3 Acceptance and relection. Rejected lots shall be screened for
all defective characteristics Removal or correction of defective units
and resubmittance of rejected lots shall be in accordance with "Acceptance
t
and Rejection ' as specified in MIL-STD-105.
4.4 Control tests.
Samples shall be selected from lots at random
4.4.1
Special samPlin&.-
using inspection level S-3 Table I of MIL-STD-105. Acceptance or rejection
of t h e lot shall be in accordance with AQL 2.5 of Table II-A of MIL-STD-105*
The samples shall have met all the requirements and tests outlined in Table
I prior to and after being subjected to the following examinations and tests~
TABLE II
TEST PROCEDURE
REQUIREMENT
CHARACTERISTIC
4.6.1
3.4
Storage at extreme temperature
301.
302. Operability at extreme temperature
3.5, 3.5.1, 3.5.2 4.6.2, 4.6.2.1, 4.6.2.2
tures
-
4.4.1.1 Failure of samPle Should any one item of a special sampling
fail to meet the specified test requirements, acceptance of the product
shall be suspended by the Government until necessary corrections have been
made by the contractor and resubmitted samples have been approved (see 4.3.3).
Unless otherwise specified in the con-
4.4.2 First article samPle.-
of t h e
conducted on o n e " u n i t
tract, test(s) listed herein shall be
initial
production sample and shall not again be performed on the remaining pro-
duction quantities, provided the manufacturing processes and techniques used
to produce the samples have not been changed or revised.
TEST PROCEDURE
REQUIREMENT
CHARACTERISTIC
4.6.3
303.
Humidity
3.6
4.6.4, 4.6.4.1
3.7,1, 3.7.1.1
Vibration
A
304.
4.4.3 Certification.- Certification shall include test data and
Certification
results for all characteristics specified in Table III.
s h a l l be p r o v i d e d
prior to performing final acceptance inspection, and r e -
This
main in effect throughout the contract for Government acceptance.
does not reMove the contractor from inspection throughout the contract
production, including recording data and results therefrom. Recorded data
a n d r e s u l t s s h a l l b e m a d e a v a i l a b l e to
A new
the Government. upon request.
7
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business