MIL-T-81527B(AS)
3.2.7 Standard Conditions - The following conditions shall be used to
establish normal performance characteristics under standard conditions and
for making laboratory bench tests.
Room Ambient: 25° +15° -5° C
Temperature
77° +27°, -9° F
Normal Ground
Altitude
None
Vibration
Humidity
Room Ambient up to 90 percent
relative humidity
115 + 1 volts (V) line to neutral, 3-phase,
Input Voltage
400 Hz + 2 percent
27.5 + O.5 volts direct current (Vdc)
Unless otherwise specified herein or in the detail
3.2.8 Warmup Time.
equipment specification, the time required for the equipment to warmup
prior to operations shall be kept to a minimum and shall not exceed 5
minutes under standard conditions, 20 minutes at extreme service condi-
tions.
3.2.9 Interference Control - The generation of radio interference by the
equipment and the vulnerability of the equipment to radio interference shall
be controlled within the limits of MIL-I-6181.
3.3 Performance.
3.3.1 General. Unless otherwise specified, values set forth to estab-
..
lish the requirements for satisfactory performance apply to performance
under both standard and extreme service conditions. When reduced perfor-
mance under the extreme conditions is acceptable, tolerances or values
setting forth acceptable variations from the performance under the standard
conditions will be specified herein or in the detail equipment specification.
The AWG-10 Side Bench Missile Control System Test
3.3.2 Function.
Set shall provide an integrated maintenance facility. This shall include
6