MIL-S-60828A(MU)
4.3.3 Acceptance and rejection.- Rejected lots shall be screened
for all defective characteristics. Removal or correction of defective
units and resubmittance of rejected lots shall be in accordance with
"Acceptance and Rejection" as specified in MIL-STD-105.
4.4 Control tests.
sampling.- Samples shall be selected from lots at
4.4.1 Special
random using inspection level S-3 Table I of MIL-STD-105. Acceptance or
rejection of the-lot shall be in accordance with AQL 2.5 of Table II-A of
MIL-STD-105. The samples shall have met all the requirements and tests
outlined in Table II prior to and after being subjected to the following
examinations and tests.
TABLE III
TEST PROCEDURE
REQUIREMENT
CHARACTERISTIC
301.
4.6.1
3.4
Storage at extreme temperatures
4.6.2
302.
operability at extreme temperatures
3.5
4.6.2.1
3.5, 3.5.1
303
Light intensity control and light
●
filament selector switch
4.6.2.2
3.5, 3.5.3
304,
Elevation mechanism and height
adjustment control
4.6.2.3
3.5, 3.5.4
Range knob
305.
3.5, 3.5.2
4.6.2.4
306.
Arm 10547473
4.4.1.1. Failure of sample.- Should any one item of a special sampling
fail to meet the specified test requirements, acceptance of the product
shall be suspended by the Government until necessary corrections have been
made by the contractor and resubmitted samples have been approved (see 4.3.3).
4.4.2 First article sample.- Unless otherwise specified in the
contract, test(s) listed herein shall be conducted on one unit of the
initial production sample and shall not again be performed on the remaining
production quantities, provided the manufacturing processes and techniques
used to produce the samples have not been changed or revised.
REQUIREMENT
TEST PROCEDURE
CHARACTERISTIC
303,
3.6
4.6.3
Humidity
4.6.4.1,
3.7.1,
304.
Vibration <General) and
Vibration A
3.7.1.1
4.6.4.1.1
4.4.3 Certification.- Certification shall include test data and
results-for all characteristics specified in Table IV. Certification
shall be provided prior to performing final acceptance inspection, and
remain in effect throughout the contract for Government acceptance. This
dock not relieve the contracted from inspection throughout the contract
8
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business