MIL-T-85068(AS)
3.4.5.9
LOW Temperature
0
0
-40 C (-40 F)
Non-operating
0
-40°c (-40 W
Operating
Acoustic environment - The equipment shall operate within
3.4.5.10
the specifications of this document in an acoustic noise level of 100 dB above a reference
level of 0.0002 microbars. The power distribution shall be continuous from 20 Hz to 9600
Hz and shall be flat (-2, +4 dB).
Standard Conditions - The following conditions Shall be used to
3.4.6
establish normal performance characteristics under standard conditions and for making
laboratory bench tests.
Room Ambient
Temperature
Normal Ground
Altitude
None
Vibration
Room Ambient
Humidity
The equipment shall operate as specified
Input Power Voltage
herein when powered from a single phase,
115 VAC, 400 Hz power source as defined
in MIL-T-21200 for military 400 Hz power.
Maximum power shall be less than 200 volt
amperes per unit.
Transportability - Transportability requirements shall be in
3.5
accordance with MIL-T-21200.
Performance - The performance of the equipment shall be as
3.6
specified herein.
3.6.1
Cable Set, Interconnecting Cable Group - A set of three inter-
connect cables shall be provided. These cables shall connect the equipment to the aircraft
as follows:
Aircraft Attachment
AWM- 87 Attachment
Cable Designation
J112 (73-J404)
W12
W12J2
W13
J113 (73-J405)
W13Jl
Umbilicals Plus Motor
W5
W5Jl
Fire Connector
Test Set, Fire Control System TS-3649/AWM-87- Operational status
3.6.2
of the radar set AN/APQ-72D, Radar Set Group A N/APA-170A and Target Intercept (Dogfight)
Computer CP-1065A, shall be measured with the Fire Control System Test Set (FCSTS). The
-7-